Electrical: Difference between revisions
From CTH Drafting Standards
Line 14: | Line 14: | ||
* C/O Decector | * C/O Decector | ||
** 1 in each hallway or area where there is a bedroom | ** 1 in each hallway or area where there is a bedroom | ||
* Attic Light | * Attic Light | ||
** Switched light if the Attic stairs are in a hallway. | ** Switched light if the Attic stairs are in a hallway. | ||
** Pullchain light if the attic stairs are in the garage. | ** Pullchain light if the attic stairs are in the garage. | ||
* Ceiling Outlet for Garage Door Opener | * Garage | ||
** 1 each for the main garage doors. Outlets are optional for Storage Room doors and other secondary doors such as a garage door opening to a back yard. | ** Ceiling Outlet for Garage Door Opener | ||
*** 1 each for the main garage doors. Outlets are optional for Storage Room doors and other secondary doors such as a garage door opening to a back yard. | |||
** 3 Outlets | |||
* Floor Outlets | * Floor Outlets | ||
** 1 outlet in the Great Room | ** 1 outlet in the Great Room | ||
Line 26: | Line 26: | ||
** 1 outlet at each vanity sink | ** 1 outlet at each vanity sink | ||
** Vent/Light/Heat (unless some other fixture is specified | ** Vent/Light/Heat (unless some other fixture is specified | ||
* Bedrooms | |||
** 1 Ceiling Fan | |||
** 1 TV cable outlet | |||
** 1 CAT 6 outlet | |||
** 1 Smoke Detector | |||
==== Optional ==== | ==== Optional ==== |
Revision as of 16:01, 6 April 2023
Standard on All Plans
- Disc Lights
- Hallways
- Pantry
- Closets (when there are lights)
- Master Bedroom (4)
- WP Outlets
- Front Porch (2)
- Rear Porch (2)
- Near A/C Pad
- Spotlight Double
- 4 on outside corners
- C/O Decector
- 1 in each hallway or area where there is a bedroom
- Attic Light
- Switched light if the Attic stairs are in a hallway.
- Pullchain light if the attic stairs are in the garage.
- Garage
- Ceiling Outlet for Garage Door Opener
- 1 each for the main garage doors. Outlets are optional for Storage Room doors and other secondary doors such as a garage door opening to a back yard.
- 3 Outlets
- Ceiling Outlet for Garage Door Opener
- Floor Outlets
- 1 outlet in the Great Room
- Bathrooms
- 1 outlet at each vanity sink
- Vent/Light/Heat (unless some other fixture is specified
- Bedrooms
- 1 Ceiling Fan
- 1 TV cable outlet
- 1 CAT 6 outlet
- 1 Smoke Detector
Optional
- Back Porch Fans
- If ceiling fans are indicated for the back porch they will be one of these options. If the plans do not indicate which one then please ask.
- Prewire for Future Fans. No fans are actually being installed. Just wiring for a fan to be installed sometime in the future.
- Customer Supplied - CTH to install. CTH does not supply ceiling fans for back porches so if they are to be installed they will be supplied by the customer.
- If ceiling fans are indicated for the back porch they will be one of these options. If the plans do not indicate which one then please ask.